ELECTRIC VACUUM CLEANER TRAINING SET
Our training set aims to help users understand the working principle of an electric vacuum cleaner and learn methods for troubleshooting potential malfunctions. With this training set, users will gain knowledge of all possible faults and their solutions in electric vacuum cleaners.
1. The training set will have a 40*40 sigma aluminum profile frame.
2. The body cover will be made of aluminum matrix composite panel with a thickness of four millimeters.
3. The front panel of the experiment set will include a connection diagram of the parts used in the operation of the set.
4. The experiment set will be mobile (movable).
5. The emergency button will be resistant to 220 V AC and up to 4 amperes.
6. The power cable will be a TTR cable with a cross-section of 3*1.5 mm and at least 3 meters long.
7. The residual current protection switch will be 220 V AC with a protection current of 30mA.
8. The training set must allow practical demonstration of the working principles of electric vacuum cleaners.
9. The training set must practically demonstrate the creation and troubleshooting of faults occurring in electric vacuum cleaners.
10. The training set will include fault buttons.
11. The training set will include residual current protection, fuse, main switch, and emergency button.
12. The training set will have a wheeled structure.
13. The dimensions of the training set will be maximum width 1000 mm, depth 1000 mm, height 1400 mm.
14. The fuse will be at least 6 A.
15. The experiment set will have an electrical grounding line.
16. The main switch will be 220 V AC, with a maximum operating current of 20 A.
17. The system will have terminal connection screws for different connections and measurements.
18. The system will include a sufficient number of test cables for various connections and measurements.
19. The training set will have a fault control panel.
20. Electrical wiring must be inside cable ducts.
21. Measured data must be displayed digitally.
22. All cables and accessories necessary for the system operation must be provided.
23. A circuit diagram must be provided alongside the device.